When the charging pile goes offline due to external network disconnection, how to ensure that the bound RFID card can still be swiped to charge via the APP?
Under normal internet connectivity, cards bound in the App are synchronized via the cloud. When online, the App syncs up to 10 bound card IDs directly into the charger's onboard MCU storage, establishing the Card-Charger-User binding relationship locally and sync with the Cloud. Afterwards, even if the charger remains offline thereafter, offline card-swipe charging start and stop are fully supported.
If the EV charger is offline, card binding will be rejected as it is impossible to esablish the Card-Charger-User binding relationship and sync with the Cloud.
Related Articles
What are the pre-network requirements and constraints for adding an RFID charging card for a charging pile in the APP settings?
1. Network Requirements: The charger must be online. Tap "Add Card" in the App, then hold the physical card near the charger's RFID reader area to pair. If offline, the operation is blocked with a toast prompt: "Please keep the device connected to ...
What is the factory RFID card configuration for EVFlow AC, and how are cards managed via the App?
No physical RFID card is bound out of the box (the physical card SKU is ZDC2505-13-eu). Users can bind and unbind cards within the App, with a maximum capacity of 10 RFID cards per device/account.
Which charging authentication/start modes does EVFlow AC support?
It supports Plug & Play (charging starts immediately upon plugging in) and Non-Plug & Play (charging requires external authentication via RFID card, Cloud, or the App).
Which charging start verification modes does EVFlow AC support?
It supports Plug & Play (charging starts immediately upon plugging in) and Non-Plug & Play (charging requires external authentication via RFID card, Cloud, or the App).
What is the default status of the "plug and charge" switch in the quick setup for charging pile initialization? What are the behavioral differences between when it is turned on and when it is turned off?
The Plug & Play switch is set to enabled by default from the factory. When enabled, the charger enters the default charging mode automatically upon plugging,without requiring extra external authentication. When disabled, charging requires both ...
Popular Articles
How to use Smart CT Mode
Smart CT Mode is a Cloud-base feature, so you need to keep the SolarFlow and the ‘sensor’ devices have stable Wi-Fi connections all the time. Smart CT Mode Introduce the function of Smart CT Mode and its advantages and disadvantages Smart CT Mode is ...
Can AB1000 and AB2000 be used together?
Yes, in configurations of up to four batteries total. For example, three AB1000s and one AB2000 can be used together.
What is the operating temperature of the AB1000/AB2000?
Charging temperature: 0-45 degrees Celsius for AB1000/ -20-45 degrees Celsius for AB2000, Discharging temperature: -20-45 degrees Celsius.
How to maintain the battery in winter
1. We recommend setting the discharge limit to 10% to prolong the lifespan of your device. 2. It is advised to set the action of the device to "Shutdown" after reaching the discharge limit. You can do this on the same page of the App. 3. In case of ...
Why is my Hub’s battery light(AB1000 LED) turned off even though I have a battery connected to it?
Check the battery status page of the Zendure App to see if all your connected batteries are recognized by the system. If no batteries are recognized, please contact support@zendure.com for further assistance. Please include a picture of the Zendure ...
Recent Articles
EVFlow AC Installation Official Tutorial Video
EVFlow AC Official Video installation link: https://www.youtube.com/watch?v=QQ4JOUNW-30
What is EVFlow AC?
EVFlow AC is a smart AC home EV charger provide 3 versions (7.4 kW, 11 kW, and 22 kW) When integrated with Zendure HEMS 2.0,it coordinates solar power, home energy storage, electricity tariffs, and household load management to optimize EV charging.
How should I clean and maintain EVFlow AC
Inspect the charger, charging cable, and connectors for wear or damage approximately every six months. Before cleaning, disconnect the upstream power supply. Use a soft, slightly damp cloth to clean the enclosure. Do not use high-pressure water jets, ...
What should I do if charging does not start after plugging in the connector or the red fault indicator appears?
First, check the following: Ensure the charging connector is fully inserted. Confirm that charging authorization has been completed. Check whether the vehicle or Zendure App has an active charging schedule limit. Verify that the selected charging ...
How can I identify the device status from the indicator light?
Under normal operating conditions, green indicates online status, while blue indicates offline status. A solid light indicates standby mode, while a breathing light indicates that charging is in progress. When the breathing light changes to a solid ...